Precipitation (in database)
- Rimco 7499 rain gauge (located approx. 30-40 m from the mast in an elevation of 1.5 m) data resolution: 0.2mm/tip, collection area 324cm2, (automatic)
Climatic Variables (in database)
1. Solar radiation
- NR01 – net-radiometer. Located on the mast. In- and outgoing long- and shortwave radiation (automatic, 10 min. average)
2. Windspeed
- Gill ultrasonic anemometer (located on the mast in an elevation of 7m above the meadow) measuring interval: 0-60 m/sec (automatic, 10 Hz, 10 min. and 30 min. average)
3. Wind direction
- Gill ultrasonic anemometer (located on the mast in an elevation of 7m above the meadow) measuring interval: 0-60 m/sec (automatic, 10 Hz, 10 min. and 30 min. average)
4. Air temperature and humidity
- HMP 45 C (located on the mast in an elevation of 5m above the meadow) (automatic, 10 min. average)
5. Soil temperature
- Sensors placed in the depths of 5cm, 10cm, and 20cm, ca. 50 m from the mast. (automatic, 10 min. average)
6. Soil heat flux
- Hukseflux plates at 5 cm depth, placed ca. 50 m from the mast. (automatic, 10 min. average)
Fluxes (not in database)
1. Water vapour and CO2
- Li-Cor LI-7500 (open path) (sensor placed on the mast in an elevation of 7 m) (automatic, 10 Hz, 30 min. average)
- Li-Cor LI-7000 (closed path) tube inlet placed at 7 m. (automatic, 10 Hz, 30 min. average)
2. CH4-flux (Not in database)
- Los Gatos DLT-100 (tube inlet placed at 7 m.) (automatic, 10 Hz, 30 min. average)
- Vacuum pump
Soil moisture (not in database)
Probe 1-20 (4 horizontal probes in the depths of 20cm, 40cm, 60cm, 80cm, and 1m)
Probe 21-24 (75cm probes)
Probe 25 (1m “groundwater-level-probe”)
Probe 26-29 (surface probes, depth 20cm, vertical)
Probe 30-33 (surface probes, depth 5cm, horizontal, probe lengths 20cm)
- 10 Decagon sensors (5TE) at 5 cm depth (logging every 30 min. connected to datalogger) Check Eline.
Suction (not in database)
- 6 Decagon tensiometers to be installed. Who is the owner?
Water table (not in database)
- Two wells established (one equipped with pressure transducer) (one with a special TDR probe)
Soil parameters (not in database)
Retention characteristics: 5 soil samples in each of 3 depth intervals down to 70 cm. Lab analyses completed. Soil hydraulic conductivity: 5 soil columns in each of 2 depth intervals down to 60 cm. Lab analyses not completed.
Other installations
- Instrument shed with power, lighting, and ventilation.
- High speed optical fibre internet connection
- Server PC
- Datalogger (Campbell 3000)
- Harddisks, 2TB
- PFI-relay (less sensitive than initial relay)
- Video camera (placed on the mast)
Pending installations
- Decagon automated sensors
Previous installations:
Decagon sensors: 5 Decagon sensors (5TE).
Click here for map and photos of the Meadow site.
Download Google Earth Placemark.